"System clock has been set back" error

If you get a "system clock has been set back" error from LM-X License Manager, LM-X has detected that your system clock has been set back. Under some circumstances, the check can return a false positive. For example, you might have accidentally changed the clock to a future time.

To resolve this problem, you should set the system clock to the correct (present) time. If you believe the error is a mistake and your system clock seems to be correct, ask your application vendor for assistance.

For more information, see System clock check. 

Why is my system clock set to a distant date in the future?

The Windows file system is based on the Gregorian calendar, which was instituted in 1582. Because of the constraints of the Gregorian calendar, you may get a “system clock has been set back” error indicating that the clock has been set back from a distant date in the future, for example:

System clock has been set back from 2022-Oct-16 17:30:49

ANSI C defines 32-bit time_t, which is interpreted as the number of seconds that have elapsed since 00:00:00 UTC on 1 January 1970 to 03:14:07 UTC on 19 January 2038.  

LM-X License Manager uses time_t, because this is the only portable representation of time across operating systems. If a file from outside the span specified by time_t (for example 1750) is detected by Windows, the Windows API changes the time to the one that fits the range represented by the time_t, thereby resulting in LM-X informing the user that system clock check has been set back from a random date.

To fix this problem, try to locate and correct the time in the affected files.

Problem with verifying system clock

If there is a problem with using lmxresetsystemclock.exe to synchronize you local system's clock with a remote time server, you may see the following error:

LM-X Error: Could not verify system clock due to failed connection with remote time server

To resolve this problem, it is necessary to verify that UDP port 123 (NTP protocol) is not blocked by a firewall.